Review




Structured Review

STEMCELL Technologies Inc easysep cell separation magnet
Easysep Cell Separation Magnet, supplied by STEMCELL Technologies Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/easysep+cell+separation+magnet/easysep+human+t+cell+isolation+kit/us12359179-759-18-22
Average 90 stars, based on 1 article reviews
easysep cell separation magnet - by Bioz Stars, 2026-10
90/100 stars

Images

Related Articles

Activation Assay:

Article Title: Peptide-mediated delivery of CRISPR enzymes for the efficient editing of primary human lymphocytes.
Article Snippet: Cells were activated (on day −2 relative to delivery) and cultured at 1 × 106 cells ml−1 for 2 days in supplemented X-VIVO 15 medium with anti-human CD3/CD28 magnetic Dynabeads (Gibco 40203D) at a bead-to-cell ratio of 1:1, 200 U ml−1 IL-2 (Proleukin), 5 ng ml−1 IL-7 (R&D Systems) and 5 ng ml−1 IL-15 (R&D Systems). .. After 2 days of activation, Dynabeads were removed from the cell culture using an EasySep cell separation magnet (STEMCELL). .. For genome editing, 200 × 103 T cells per well were suspended in 100 μl Opti-MEM (Gibco) (treatments detailed below).

Article Title: Peptide-mediated delivery of CRISPR enzymes for the efficient editing of primary human lymphocytes.
Article Snippet: Isolated NK cells were cultured at 1 × 106 cells ml−1 for 6 days in X-VIVO 15 medium (Lonza) supplemented with 5% FBS, 50 μM 2-mercaptoethanol and 10 mM N-acetyl-l-cysteine and 1,000 U ml−1 IL-2 (Proleukin), and activated with MACSiBead particles pre-loaded with anti-human CD335 (NKp46) and anti-human CD2 antibodies (Miltenyi Biotec). .. After 6 days of activation, MACSiBead particles were removed from the cell culture using an EasySep cell separation magnet (STEMCELL). .. For genome editing, 200 × 103 NK cells per well were suspended in 100 μl consisting of a mixture of Opti-MEM (Gibco) and up to 20% peptide:RNP formulation (treatments detailed below).

Cell Culture:

Article Title: Peptide-mediated delivery of CRISPR enzymes for the efficient editing of primary human lymphocytes.
Article Snippet: Cells were activated (on day −2 relative to delivery) and cultured at 1 × 106 cells ml−1 for 2 days in supplemented X-VIVO 15 medium with anti-human CD3/CD28 magnetic Dynabeads (Gibco 40203D) at a bead-to-cell ratio of 1:1, 200 U ml−1 IL-2 (Proleukin), 5 ng ml−1 IL-7 (R&D Systems) and 5 ng ml−1 IL-15 (R&D Systems). .. After 2 days of activation, Dynabeads were removed from the cell culture using an EasySep cell separation magnet (STEMCELL). .. For genome editing, 200 × 103 T cells per well were suspended in 100 μl Opti-MEM (Gibco) (treatments detailed below).

Article Title: Peptide-mediated delivery of CRISPR enzymes for the efficient editing of primary human lymphocytes.
Article Snippet: Isolated NK cells were cultured at 1 × 106 cells ml−1 for 6 days in X-VIVO 15 medium (Lonza) supplemented with 5% FBS, 50 μM 2-mercaptoethanol and 10 mM N-acetyl-l-cysteine and 1,000 U ml−1 IL-2 (Proleukin), and activated with MACSiBead particles pre-loaded with anti-human CD335 (NKp46) and anti-human CD2 antibodies (Miltenyi Biotec). .. After 6 days of activation, MACSiBead particles were removed from the cell culture using an EasySep cell separation magnet (STEMCELL). .. For genome editing, 200 × 103 NK cells per well were suspended in 100 μl consisting of a mixture of Opti-MEM (Gibco) and up to 20% peptide:RNP formulation (treatments detailed below).

Magnetic Cell Separation:

Article Title: NOTCH3 signalling controls human trophoblast stem cell expansion and differentiation.
Article Snippet: To remove possible contamination with TSCs that have spontaneously differentiated into HLA-G+ EVTs, harvested cells were re-suspended in MACS buffer (MACS Miltenyi Biotec) followed by magnetic cell separation of HLA-G-negative cells using HLA-G-PE antibodies (PE1P-292-C100, Exbio) and anti-PE MicroBeads (MACSMiltenyi Biotec), as instructed by the manufacturer. .. As fused TSCs are large and would become stuck in the MACS column, negative selection of forskolin-treated cells was performed by using an EasySep cell separation magnet (StemCell Technologies). ..

Article Title: NOTCH3 signalling controls human trophoblast stem cell expansion and differentiation
Article Snippet: To remove a possible contamination with TSCs that have spontaneously differentiated into HLA-G + EVTs, harvested cells were re-suspended in MACS buffer (MACS Miltenyi Biotec) followed by magnetic cell separation of HLA-G-negative cells using HLA-G-PE antibodies (PE1P-292-C100, Exbio) and anti-PE MicroBeads (MACS Miltenyi Biotec) as instructed by the manufacturer. .. As fused TSCs are large and would become stuck in the MACS column, negative selection of forskolin-treated cells was performed by using EasySep cell separation magnet (stemcell technologies). ..

Selection:

Article Title: NOTCH3 signalling controls human trophoblast stem cell expansion and differentiation.
Article Snippet: To remove possible contamination with TSCs that have spontaneously differentiated into HLA-G+ EVTs, harvested cells were re-suspended in MACS buffer (MACS Miltenyi Biotec) followed by magnetic cell separation of HLA-G-negative cells using HLA-G-PE antibodies (PE1P-292-C100, Exbio) and anti-PE MicroBeads (MACSMiltenyi Biotec), as instructed by the manufacturer. .. As fused TSCs are large and would become stuck in the MACS column, negative selection of forskolin-treated cells was performed by using an EasySep cell separation magnet (StemCell Technologies). ..

Article Title: NOTCH3 signalling controls human trophoblast stem cell expansion and differentiation
Article Snippet: To remove a possible contamination with TSCs that have spontaneously differentiated into HLA-G + EVTs, harvested cells were re-suspended in MACS buffer (MACS Miltenyi Biotec) followed by magnetic cell separation of HLA-G-negative cells using HLA-G-PE antibodies (PE1P-292-C100, Exbio) and anti-PE MicroBeads (MACS Miltenyi Biotec) as instructed by the manufacturer. .. As fused TSCs are large and would become stuck in the MACS column, negative selection of forskolin-treated cells was performed by using EasySep cell separation magnet (stemcell technologies). ..



Similar Products

90
STEMCELL Technologies Inc easysep cell separation magnet
Easysep Cell Separation Magnet, supplied by STEMCELL Technologies Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/easysep+cell+separation+magnet/easysep+human+t+cell+isolation+kit/us12359179-759-18-22
Average 90 stars, based on 1 article reviews
easysep cell separation magnet - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
STEMCELL Technologies Inc bead-based magnetic separation easysep mouse t cell untouched isolation kit
Bead Based Magnetic Separation Easysep Mouse T Cell Untouched Isolation Kit, supplied by STEMCELL Technologies Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/easysep+cell+separation+magnet/magnetic+bead+separation+easysep+human+resting+cd4++t+cell+isolation+kit/pm40593800-316-13-23
Average 90 stars, based on 1 article reviews
bead-based magnetic separation easysep mouse t cell untouched isolation kit - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
STEMCELL Technologies Inc magnetic separation easysep human cd4+ t cell isolation kit
Magnetic Separation Easysep Human Cd4+ T Cell Isolation Kit, supplied by STEMCELL Technologies Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/easysep+cell+separation+magnet/magnetic+bead+separation+easysep+human+resting+cd4++t+cell+isolation+kit/pmc11358443-418-10-17
Average 90 stars, based on 1 article reviews
magnetic separation easysep human cd4+ t cell isolation kit - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
STEMCELL Technologies Inc easyeights easysep magnet cell separator
Easyeights Easysep Magnet Cell Separator, supplied by STEMCELL Technologies Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/easysep+cell+separation+magnet/easyeights+easysep+magnet/pm39073814-46-24-29
Average 90 stars, based on 1 article reviews
easyeights easysep magnet cell separator - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
STEMCELL Technologies Inc magnetic cell separation system easysep direct human neutrophil isolation kit
Magnetic Cell Separation System Easysep Direct Human Neutrophil Isolation Kit, supplied by STEMCELL Technologies Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/easysep+cell+separation+magnet/magnetic+cell+separation+system+easysep+direct+human+neutrophil+isolation+kit/pmc11239672-388-20-26
Average 90 stars, based on 1 article reviews
magnetic cell separation system easysep direct human neutrophil isolation kit - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
STEMCELL Technologies Inc magnetic separation mouse total t cell easysep
Magnetic Separation Mouse Total T Cell Easysep, supplied by STEMCELL Technologies Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/easysep+cell+separation+magnet/magnetic+cell+separation+method/pmc10294141-297-9-16
Average 90 stars, based on 1 article reviews
magnetic separation mouse total t cell easysep - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
STEMCELL Technologies Inc magnetic separation mouse cd8 t cell easysep
Magnetic Separation Mouse Cd8 T Cell Easysep, supplied by STEMCELL Technologies Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/easysep+cell+separation+magnet/magnetic+cd8++t+cell+selection+beads+easysep/pmc10294141-307-21-28
Average 90 stars, based on 1 article reviews
magnetic separation mouse cd8 t cell easysep - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

Image Search Results